.. _auto_curves_effective_remove_localization: *UPDATE TO REMOVE LOCALIZATION* =============================== Detects the onset of localization in an effective stress–strain curve by comparing an input (test/baseline) curve against a simulation output curve using a configurable ratio threshold. From the detected localization point onward, the curve is extended via iso-parametric scaling in both X and Y directions. Use this worker to produce a physically consistent post-necking tail for MAT_24-style plasticity input. When to use ----------- Classification: **process**. Tagged: ``MAT_24``, ``curve_update``, ``effective_stress``, ``iso-parametric_scaling``, ``localization``, ``post-necking``, ``stress_strain``. Inputs ------ .. list-table:: :header-rows: 1 :widths: 20 20 20 20 20 20 * - Label - ID - Type - Default - Required - Description * - Input Effective Stress - input_effective_stress - vector - — - - Reference effective stress–strain curve (typically from a physical test or baseline simulation) used as the target to detect the localization onset point; supply as a vector of (strain, stress) pairs in consistent units. * - Output Effective Stress - output_effective_stress - vector - — - - Effective stress–strain curve from the current simulation that is compared against the input reference to identify where localization begins; supply as a vector of (strain, stress) pairs in the same units as the input curve. * - Ratio to detect Localization - ratio - scalar - 0.05 - - Dimensionless threshold ratio (default 0.05): localization is flagged at the first point where the absolute difference between the two curves exceeds this fraction of the input curve's y-value; increase to allow larger divergence before truncation. * - Scale Factor - sf - scalar - 2.0 - - Y-axis iso-parametric scale factor applied beyond the localization point (default 2.0); controls how steeply the stress is extrapolated after necking — leave at default for a typical steel post-necking tail. * - X-Scale Factor - xsf - scalar - 1.0 - - X-axis iso-parametric scale factor applied beyond the localization point (default 1.0, i.e. no X-scaling); increase above 1.0 to stretch the strain range of the extrapolated post-localization segment. Outputs ------- .. list-table:: :header-rows: 1 :widths: 20 20 20 20 * - Label - ID - Type - Description * - updated_curve - updated_curve - vector - Effective stress–strain curve with the post-localization segment replaced by the iso-parametrically scaled extension; returned as a vector of (strain, stress) pairs ready for direct use as a plasticity input curve (e.g., MAT_24 LCSS). Disciplines ----------- - data.curve.transform - engineering.material.calibration - engineering.material.characterization Runnable example ---------------- A runnable example is registered for this worker. Open the example workflow on the d3VIEW canvas: `/api/workflow/example?id=curves_effective_remove_localization `_ .. raw:: html

Auto-generated from transformation schema. Worker id: curves_effective_remove_localization. Schema hash: c000f69fcdeb. Hand-curated docs in workerexamples/ override this page when present.