.. _auto_material_specimen_generator_cylinder: *MATERIAL SPECIMEN GENERATOR* ============================= Generates a cylindrical material test specimen deck (LS-DYNA keyword file) for coupon-level compression or tension simulations. Select the cylinder geometry variant, element formulation, and loading definition to produce a ready-to-run input file. Use this worker when you need a parameterised cylindrical specimen for material characterisation or calibration workflows. When to use ----------- Classification: **data**. Tagged: ``LS-DYNA``, ``VAD``, ``compression``, ``coupon``, ``cylinder``, ``deck_authoring``, ``elform``, ``keyword``. Inputs ------ .. list-table:: :header-rows: 1 :widths: 20 20 20 20 20 20 * - Label - ID - Type - Default - Required - Description * - Type - type - string - cylinder_h6mmd6mm_1mm - - Cylindrical specimen geometry variant to generate; 'cylinder_h6mmd6mm_1mm' (1 mm element size) or 'cylinder_h6mmd6mm_p3mm' (0.3 mm element size) — defaults to the 1 mm variant when left unchanged. * - Elform - elform - scalar - -1 - - LS-DYNA element formulation ID applied to all solid elements in the specimen deck (e.g. -1 = fully-integrated, 1 = under-integrated); defaults to -1. * - Mass-Scaled Time Step - mass-scaled_time_step - scalar - 0 - - Target minimum time step (seconds) for mass scaling via *CONTROL_TIMESTEP; set to 0 (default) to disable mass scaling. * - V-A-D - velocity-acceleration-displacement - scalar - 2 - - VAD flag that controls how the load curve is interpreted: 0 = displacement, 1 = acceleration, 2 = velocity (default); maps directly to the VAD field in *BOUNDARY_PRESCRIBED_MOTION. * - Loading Input - loading_input_type - scalar - constant - - Defines whether the applied loading magnitude is a single constant value ('constant', default) or a user-supplied time–history curve ('curve'). * - Displacement Or Velocity Or Acceleration Value - displacementor_velocityor_acceleration_value - scalar - 25 - - Magnitude of the prescribed displacement (mm), velocity (mm/ms), or acceleration (mm/ms²) applied to the specimen, depending on the VAD setting; active only when Loading Input Type is 'constant' (default 25). * - Duration - duration - scalar - 100 - - CONTROL_TERMINATION * - Binary Output Frequency - binary_output_frequency - scalar - 1 - - * - ASCII Output Frequency - ascii_output_frequency - scalar - 0.1 - - * - Material Data - material_data - text - — - - Material Card * - IMFLAG - imfla_g - scalar - 0 - - * - IMASS - imas_s - scalar - 0 - - * - DT0 - d_t0 - scalar - 0.1 - - * - ILIMIT - ilimi_t - scalar - 10 - - * - MAXREF - maxre_f - scalar - 15 - - * - IACC - iac_c - list - 0 - - * - Additional Keywords - additionalkeywords - text - — - - Add additional keywords (Optional) Outputs ------- .. list-table:: :header-rows: 1 :widths: 20 20 20 20 * - Label - ID - Type - Description * - material_specimen_generator_cylinder_output_1 - material_specimen_generator_cylinder_output_1 - text - LS-DYNA keyword (.k) deck for the configured cylindrical specimen, including mesh, boundary conditions, and prescribed loading, ready for solver submission or further material-card insertion. Disciplines ----------- - cae.preprocessing.deck_authoring - engineering.material.specimen .. raw:: html

Auto-generated from transformation schema. Worker id: material_specimen_generator_cylinder. Schema hash: 41b3940bd9ff. Hand-curated docs in workerexamples/ override this page when present.