.. _auto_physicaltest_validate_body_sensitivity: *VALIDATE BODY SENSITIVITY TEST DATA* ===================================== Validates body sensitivity (NVH body characterisation) physical-test data against a configurable set of signal-quality checks including coherence, PSD roll-off/growth, driving-point repeatability, cross-point reciprocity, driving-point symmetry, and driving-point orientation. Use this worker to gate body sensitivity test results before they are consumed by downstream NVH or correlation workflows. When to use ----------- Tagged: ``body_sensitivity``, ``coherence``, ``driving_point``, ``nvh``, ``physical_test``, ``psd``, ``reciprocity``, ``repeatability``. Inputs ------ .. list-table:: :header-rows: 1 :widths: 20 20 20 20 20 20 * - Label - ID - Type - Default - Required - Description * - Physicaltest - input_pt_id - remote_lookup - — - - One or more physical-test records to validate, selected by remote lookup against the platform physicaltests datastore; repeatable to batch-validate multiple tests in a single run. * - Choose Checks To Perform - checks - select - all - - Multi-select list of validation checks to execute; defaults to 'all', which runs every available check (coherence, psd_roll_off, psd_growth, dr_repeatability, cp_reciprocity, dr_symmetric, dr_orientation). * - Min Coherence - min_coherence - scalar - 0.9 - - Minimum acceptable coherence value (dimensionless, 0–1) over the coherence frequency band; default 0.9 — lower only if the test setup warrants looser acceptance. * - Coherence Freq Start - min_coherence_freq - scalar - 50 - - Lower bound of the coherence check frequency band in Hz; default 50 Hz. * - Coherence Freq End - max_coherence_freq - scalar - 800 - - Upper bound of the coherence check frequency band in Hz; default 800 Hz. * - PSD Freq Start - min_psd_freq - scalar - 50 - - Lower bound of the PSD roll-off and growth check frequency band in Hz; default 50 Hz. * - PSD Freq End - max_psd_freq - scalar - 1000 - - Upper bound of the PSD roll-off and growth check frequency band in Hz; default 1000 Hz. * - PSD Rolloff Limit - psd_rolloff_limit - scalar - 6 - - Maximum allowable PSD roll-off in dB/decade (or equivalent slope unit) before the check flags a failure; default 6. * - PSD Growth Limit - psd_growth_limit - scalar - 3 - - Maximum allowable PSD growth in dB over the defined frequency band before the check flags a failure; default 3. * - DPRFS - dr_min_repeat_freq - scalar - 50 - - Lower bound of the driving-point repeatability check frequency band in Hz (DPRFS); default 50 Hz. * - DPRFE - dr_max_repeat_freq - scalar - 80% - - Upper bound of the driving-point repeatability check frequency band; accepts a Hz value or a percentage string such as '80%' meaning 80 % of the Nyquist/analysis frequency (DPRFE); default '80%'. * - DPRRP - dr_repeatability_run_pairs - text - — - - Comma- or space-delimited run-pair identifiers used to compare repeated driving-point measurements for repeatability; depends on input_pt_id — leave blank to use all available run pairs (DPRRP). * - DPRET - dr_repeatability_error_limit - scalar - 0.01 - - Maximum acceptable RMS error (dimensionless ratio) between repeated driving-point runs; default 0.01 (1 %) (DPRET). * - DPSFS - dr_min_symm_freq - scalar - 50 - - Driving Point Symm Freq Start * - DPSFE - dr_max_symm_freq - scalar - 80% - - Driving Point Symm Freq End * - DPSRET - dr_symmetric_error_limit - scalar - 0.01 - - Driving Point Symmetric Response Error Tolerance * - DPOFS - dr_min_orien_freq - scalar - 50 - - Driving Point Orien Freq Start * - DPOFE - dr_max_orien_freq - scalar - 1000 - - Driving Point Orien Freq End * - CRRP - cr_reciprocity_run_pairs - text - — - - Cross-Point Reciprocity Run Pairs * - CRET - cr_reciprocity_error_limit - scalar - 0.01 - - Cross-Point Reciprocity Error Tolerance Outputs ------- .. list-table:: :header-rows: 1 :widths: 20 20 20 20 * - Label - ID - Type - Description * - Physicaltest Id - physicaltest_id - integer - Integer primary key of the validated physical-test record in the platform physicaltest datastore, enabling downstream workers to reference the result directly. * - Failed Report - failed_report - dataset - Editable dataset listing every check that failed — columns include test ID, check name, measured value, limit, and pass/fail status — to support triage and sign-off workflows. Disciplines ----------- - data.correlation - data.dataset.ingest - data.signal_processing - engineering.nvh - platform.workflow .. raw:: html
Auto-generated from platform schema. Worker id: physicaltest_validate_body_sensitivity. Schema hash: b9529a74ee70. Hand-curated docs in workerexamples/ override this page when present.