Enforces derivative monotonicity on a stress-strain (or similar) curve by treating the Young’s modulus / plastic-entry region (YPE), ensuring the slope does not decrease non-physically before the specified strain limit. Use this worker to clean up noisy or non-monotonic hardening curves prior to material calibration or LS-DYNA MAT_24 ingestion.

When to use

Classification: process.

Tagged: YPE, curve, derivative, hardening, mat_24, monotonicity, smoothing, stress_strain.

Inputs

Label ID Type Default Required Description
Curve curve vector   Input stress-strain (or generic X-Y) curve as a two-column vector; this is the curve whose derivative will be checked and corrected for monotonicity.
Xlimit xlimit float 0.05   Upper X-axis limit (e.g. strain) up to which the derivative-monotonicity correction is applied; defaults to 0.05 (5 % strain) — increase for materials with a wide elastic-to-plastic transition.
Scalefactor scalefactor float 1   Multiplicative scale factor applied to the curve Y-values before processing; defaults to 1.0 (no scaling) — change only when unit conversion is needed in the same step.

Outputs

Label ID Type Description
curve_enforce_derivative_monotonicity_output_1 curve_enforce_derivative_monotonicity_output_1 vector Corrected curve with a monotonically non-decreasing derivative up to xlimit, returned as a two-column vector in the same X-Y format as the input.

Disciplines

  • data.curve.transform
  • engineering.material.calibration
  • engineering.material.characterization