GET FEMUR INTERCEPTS BY OCCUPANT TYPE AND MEAS TYPE

Looks up the standardised femur axial force intercept value for a given occupant dummy type and load type, applying an optional scale factor. Use this worker to retrieve the regulatory/assessment threshold intercept needed for femur injury criterion calculations in occupant safety post-processing.

When to use

Classification: process.

Tagged: axial_force, crabi, dummy, femur, hybridiii, injury_criteria, intercept, occupant_safety.

Inputs

Label ID Type Default Required Description
Occupant Type occupant_type scalar crabi_12_month_old_infant   Dummy/occupant type whose femur intercept is to be retrieved; choose from CRABI 12-month infant, Hybrid III 3YO, 6YO, small female, or mid-sized male (default: crabi_12_month_old_infant).
Measurement Type measurement_type scalar force   Measurement type
Scale scale text 1   Multiplicative scale factor applied to the returned intercept value; leave at default (1) to return the unscaled regulatory intercept.

Outputs

Label ID Type Description
injury_get_femur_intercept_output_1 injury_get_femur_intercept_output_1 text The (optionally scaled) femur intercept threshold value for the selected occupant type and load type, returned as a numeric text string in the native force units (typically kN).

Disciplines

  • cae.postprocessing.response
  • engineering.crash.occupant_safety

Auto-generated from transformation schema. Worker id: injury_get_femur_intercept. Schema hash: 2fe0bc706b8f. Hand-curated docs in workerexamples/ override this page when present.